ICODE SLIX2 Command Audit

Date: 2026-03-17 Source: SL2S2602 datasheet Rev 4.2, AN11809 Rev 1.2, SL2S2002 datasheet Rev 3.4

Status

Commands marked OK are implemented in firmware native handler or response table. Commands marked MISSING need implementation in the Python transponder model + table compiler.

Standard ISO 15693 (firmware native handler)

Cmd Name Status
0x01 INVENTORY OK
0x02 STAY QUIET OK
0x20 READ SINGLE BLOCK OK (with lock_mode access control)
0x21 WRITE SINGLE BLOCK OK (with lock_mode access control)
0x22 LOCK BLOCK OK (firmware native)
0x23 READ MULTIPLE BLOCKS OK
0x25 SELECT OK
0x26 RESET TO READY OK
0x27 WRITE AFI OK (firmware native)
0x28 LOCK AFI OK (firmware native)
0x29 WRITE DSFID OK (firmware native)
0x2A LOCK DSFID OK (firmware native)
0x2B GET SYSTEM INFO OK
0x2C GET MULTIPLE BLOCK SECURITY OK

NXP Custom Commands (table entries)

Code Name Status Priority Notes
0xA0 INVENTORY READ MISSING Nice to have Like inventory but returns data blocks
0xA1 FAST INVENTORY READ MISSING Nice to have Same as A0 at double data rate
0xA2 SET EAS MISSING Nice to have Enables EAS mode (password protected)
0xA3 RESET EAS MISSING Nice to have Disables EAS mode
0xA4 LOCK EAS MISSING Nice to have Permanently locks EAS state
0xA5 EAS ALARM MISSING Nice to have Returns 256-bit EAS sequence
0xA6 PASSWORD PROTECT EAS/AFI MISSING Nice to have Enables password protection for EAS/AFI
0xA7 WRITE EAS ID MISSING Nice to have Writes 16-bit EAS identifier
0xAB GET NXP SYSTEM INFO MISSING Must have Returns PP, PP conditions, lock bits, feature flags
0xB2 GET RANDOM NUMBER OK - Firmware native handler
0xB3 SET PASSWORD OK - Firmware native + table entries
0xB4 WRITE PASSWORD MISSING Should have Changes password value (requires prior SET PASSWORD)
0xB5 LOCK PASSWORD MISSING Should have Permanently locks a password
0xB6 PROTECT PAGE MISSING Must have Sets protection pointer + access conditions
0xB7 LOCK PAGE PROTECTION MISSING Should have Permanently locks protection config
0xB9 DESTROY MISSING Should have Irreversibly kills tag (XOR password)
0xBA ENABLE PRIVACY MISSING Must have Enters privacy mode (separate from SET PASSWORD)
0xBB 64-BIT PASSWORD PROTECTION MISSING Should have Requires both R+W passwords
0xBC STAY QUIET PERSISTENT MISSING Nice to have Persistent quiet survives power cycles
0xBD READ SIGNATURE MISSING Must have Returns 32-byte ECC originality signature

Model Issues

  1. Password ID 0x10 (EAS/AFI) missing — datasheet lists 5 IDs: 0x01=Read, 0x02=Write, 0x04=Privacy, 0x08=Destroy, 0x10=EAS/AFI. Model only has 4.

  2. Privacy mode behavior — datasheet says tag responds to GET RANDOM NUMBER AND SET PASSWORD in privacy mode. Model only allows SET PASSWORD.

  3. ENABLE PRIVACY (0xBA) is separate from SET PASSWORD — uses XOR'd password, specifically enters privacy mode. Model conflates with SET PASSWORD pwd_id=privacy.

  4. 16-bit counter (block 79) has special increment-only semantics via WRITE with specific data format. Not modeled.

  5. Protection pointer access conditions — datasheet defines Page L / Page H with separate read/write protection bits (Extended Protection Status byte). Model uses simpler protection_pointer integer.

Implementation Priority

Next session — must haves:

  1. GET NXP SYSTEM INFO (0xAB) — static response from tag config
  2. READ SIGNATURE (0xBD) — static 32-byte signature
  3. ENABLE PRIVACY (0xBA) — XOR password, enter privacy mode
  4. EAS/AFI password (pwd_id 0x10) — add to model
  5. PROTECT PAGE (0xB6) — set protection pointer via RF

After that — should haves: 6. WRITE PASSWORD (0xB4) 7. LOCK PASSWORD (0xB5) 8. DESTROY (0xB9) 9. LOCK PAGE PROTECTION (0xB7) 10. 64-BIT PASSWORD PROTECTION (0xBB)

Later — nice to haves: 11-16. EAS subsystem, INVENTORY READ, STAY QUIET PERSISTENT, counter handling